    General features
    - Conventional single-phase UPS systems, available in 3 versions depending on the power
    - Power from 1 to 3 kVA
    - VFI-SS-111 on-line double conversion
    - RS232 communication port
    - LAN / SNMP connectivity
    - Uptime can be extended with additional battery cabinets
    - Compact design and low footprint

    The Legrand UPS Keor LP model is a UPS using high frequency PWM technology, On Line Double Conversion type, solid neutral, Rated Power 1000, 2000, 3000 VA, equipped with valve-regulated hermetic-type batteries, contained inside the UPS in a specific compartment or in one or more external cabinets, sized to guarantee a minimum autonomy of 5 minutes at 70% of the load.

    Keor LP is available with different types of output sockets:
    3 101 54 - 3 IEC sockets 10A
    3 101 55 - 3 IEC sockets 10A plus an french standard sockets
    3 101 56 - 6 IEC sockets 10A
    3 101 57 - 6 IEC sockets 10A plus 2 french standard sockets
    3 101 58 - 3 IEC sockets 10A
    3 101 59 - 6 IEC sockets 10A plus 2 french standard sockets

    The UPS rectifier is comprised of a control and regulation circuit (PFC), which in addition to the functions of a normal rectifier it also:
    • automatically correct the power factor of the load bringing it to a value 0.98 with the load already applied in output at 20% of the rated load;
    • power the inverter without requiring energy from the batteries even when there is a very low network voltage
    • guarantee a total harmonic distortion of the input current THDIin < 10% without the addition of filters or supplementary parts.

    The bypass circuit is designed and built in compliance with the following:
    - Electromechanical switching device
    - Command and control logic managed by the microprocessor which:
    • automatically transfers the load directly to the primary network without interrupting the power supply, in conditions of overload, overheating, continuous voltage outside of the tolerances and inverter fault;
    • automatically re-transfer the load from the primary network to the inverter line, without interrupting the power supply, when the normal conditions of the load are restored;
    • if the primary network and inverter are not synchronised, the bypass must be disabled.

    A diagnostic and shutdown software (UPS Communicator), if installed accordingly on a PC connected to the UPS, allows you to access all of the operating data, regulate and set special functions
    and control the shut down of Windows and Linux operating systems.

    An optional software (UPS Management software) provides hierarchical multiserver shutdown and remote UPS management for any operating system in a heterogeneous network (Windows, Novell, Mac, Linux and the most common Unix).

    Keor LP is managed by a microprocessor and is capable of displaying alarms and operating modes on a LED control panel, as described below:
    • normal operation
    • battery operation
    • bypass operation
    • overload
    • generic fault
    • end of back-up time

    The Static Keor LP UPS has the CE marking, pursuant to Directives 73/23, 93/68, 89/336, 92/31, 93/68 and is designed and built in compliance with the following standards:
    • EN 62040-1 “General and safety requirements for UPS used in operator access areas”
    • EN 62040-2 “Electromagnetic compatibility (EMC) requirements”

    Available accessories:
    Additional battery charger for battery cabinet 1000 VA 310958
    Additional battery charger for battery cabinet 2000 VA 310960
    Additional battery charger for battery cabinet 3000 VA 310961
    Bypass 310953

    General Features
    Type of operation: On line double conversion
    Neutral Connectivity: Solid neutral
    Wave shape in networked operation: Sinusoidal
    Wave shape in battery operation: Sinusoidal
    Switching time: None

    General Features
    Rated input voltage: 230 V
    Input voltage interval:
    - 210÷240V at 100% load
    - 185÷260V at 80% load
    - 160÷300V at 70% load
    Input frequency: 45-65Hz ± 2% Autosensing
    Power factor: > 0.98

    Output features (network operation)
    Rated output voltage: 230 V ± 1%
    Rated/active output power:
    - 1.000 VA / 900 W
    - 2.000 VA / 1800 W
    - 3.000 VA / 2700 W
    Total harmonic distortion of the output voltage on linear rated load: < 1 %
    Total harmonic distortion of the output voltage on non-linear rated load, P.F.=0.7: < 4 %
    Rated output frequency: 50 Hz or 60 Hz +/- 0,1%
    Tolerance on the output frequency: Synchronised to the input frequency; ± 1% when not synchronised
    Crest factor on the output current: 3:1
    Overload capacity:
    • ONLINE mode: <105%
    • for at least 10 second: 121÷150%
    • for at least 30 seconds: 106÷120%
    • instant transfer to bypass: >151%

    Battery features
    Type of battery: Lead-acid, sealed, maintenance-free
    Unitary capacity: 7 Ah (12V)
    Battery module voltage:
    - 1000 - 24Vdc
    - 2000 - 48 Vdc
    - 3000 - 72 Vdc
    Dimensions of battery cabinet (H x W x D) (mm): 322x151x444 mm
    Battery cabinet Net weight (kg): 31

    Environmental Specifications
    Noise level measured at 1 meter:
    Range of operating temperature: From 0°C to +40°C
    Range of operating relative humidity: 20-80% non-condensing
    Degree of protection: IP21

    Manufacturing Specifications
    Maximum weight*:
    - 1000 - 10 Kg
    - 2000 - 17 Kg
    - 3000 - 23 Kg
    Maximum dimensions (W×L×H):
    - 1000 - 236x144x367 mm
    - 2000 - 322x151x444 mm
    - 3000 - 322x151x444 mm
    Type of switching: High frequency PWM
    Rectifier/booster/inverter technology: MOSFET
    Interfaces: 1 RS232 serial port, 1 slot for network interface connection (ex. CS121)

    *Maximum weight referring to a configuration with a back-up time of 10 minutes at 80% of the rated load.

    Backup time

    (min)

    Keor LP

    50%

    70%

    80%

    1000

    6

    5

    3

    2000

    7

    5

    3

    3000

    7

    5

    3

    1000 + 1 battery cabinet

    99

    68

    60

    2000 + 1 battery cabinet

    54

    32

    28

    3000 + 1 battery cabinet

    41

    24

    16

    1000 + 2 battery cabinet

    184

    134

    118

    2000 + 2 battery cabinet

    100

    69

    61

    3000 + 2 battery cabinet

    69

    50

    43

    NOTE: The stated back-up times in minutes are estimated and may vary according to the load characteristics, operating conditions and environment.


    Parametre

    Nabíjačky a batérie

    Kategória

    ups on-line

    Výstupné zásuvky

    6x IEC zásuvka

    Výstupný prúd

    10 A

    Odporúčané použitie

    profesionálne

    Port

    1x RS232

    Výkon a formát

    Formát UPS

    Fyzicky tvar UPS (tower, rack, racktower a kompaktné)

    tower

    Zdanlivý výkon

    Zdanlivý výkon UPS, udávaný vo voltampéroch (VA), je kľúčovým parametrom pri výbere záložného zdroja energie. Tento výkon predstavuje celkovú elektrickú kapacitu, ktorú môže UPS poskytnúť príslušenstvu a zariadeniam v prípade výpadku prúdu. Pri výbere UPS je dôležité zvážiť nielen zdanlivý výkon, ale aj skutočný výkon v wattoch (W), ktorý odráža reálnu spotrebu pripojených zariadení. Pre optimálnu ochranu a efektivitu by mal byť výkon UPS o približne tretinu vyšší než celková spotreba energie zariadení.

    2000 VA

    Čas zálohovania

    Orientačná doba zálohy

    Orientačná doba zalohy pri zariadení ktoré ma spotrebu 100W.

    100W/ 50 minút

    OPÝTAJTE SA PORADCU

    Datacomp poradca

    Produkt manažér:

    Miroslav, Datacomp

    lizon.miroslav@datacomp.sk
    Notebooky